GZ-160/25 molecular sieve high pressure dryer
2024-07-19 14:06Technical parameters: Working medium: C2H2 Handling gas volume: 160M3 /H Working pressure: 1.6~2.5MPa Working temperature: 30℃ Moisture content of C2H2: saturated steam Moisture content of C2H2 after treatment: 0.2~0.5g H2O/M3 Operation mode: no heat, no electricity and fully automatic Switching cycle: 20Min Drying time: 10Min Regeneration time: about 8Min Pressure equalization time: about 2Min Regeneration gas volume: 12~24M3 /H Instrument air consumption: 0.3M3/H, -30℃ no oil at dew point Instrument air pressure: 0.5~0.7MPa
Main components of dryer and desiccant: Adsorber: 2pieces Heat exchanger: 1piece Pneumatic ball valve: 6pieces Check valve: 4pieces Regeneration gas flowmeter: 1piece Assembly support: 1piece Control cabinet: 1piece 3A molecular sieve: 80Kg